Whether you are managing a chemical reactor or a backyard aquarium, the Fourtech Temperature Controller

Temperature Controller Parameter Setting #PID #Controller with #SSR

Press the SET key briefly. The SV display will begin to flash.

| Parameter | Name | What it does | Typical Setting | | :--- | :--- | :--- | :--- | | AL1 | Alarm 1 | Triggers a relay if temp exceeds this limit | 5-10° above SV | | P | Proportional Band | How aggressive the controller reacts | Default (often 30) | | I | Integral Time | Removes long-term error | Default (often 240) | | d | Derivative Time | Prevents overshoot | Default (often 60) | | t | Cycle Time | How fast the SSR/Relay switches | 1 sec (SSR) / 20 sec (Relay) | | LCK | Lock | Prevents accidental setting changes | 0 (Unlocked) / 1 (Locked) |

: The controller typically supports multiple sensor types, including K and J thermocouples Pt100 RTDs

Control Output: Use a Solid State Relay (SSR) for precise PID control or a standard mechanical relay for simple ON-OFF tasks. 2. Front Panel Layout